Back to top
Flash Meter Arrestor

Flash Meter Arrestor

Product Details:

  • Output Voltage 230-440 V AC
  • Diameter Standard
  • Power Consumption Low
  • Automation Grade Manual
  • Application Used for protecting energy meters from electrical surges and flashes
  • Power Source Electric
  • Phase Single/Three Phase
  • Click to View more
X

Flash Meter Arrestor Price And Quantity

  • 150 Piece

Flash Meter Arrestor Product Specifications

  • As per application
  • Single/Three Phase
  • Metal & Polymer
  • Electric
  • Suitable for standard metering applications
  • Standard
  • 230-440 V AC
  • 230-440 V AC
  • New
  • Manual
  • 230-440 V
  • Used for protecting energy meters from electrical surges and flashes
  • Low
  • Standard (customized as per requirement)
  • 0-100 A
  • 50-60 Hz
  • Electrical Protection Device
  • Flash Meter Arrestor
  • Up to 100 A
  • -10C to +60C
  • High voltage and lightning protection
  • Indoor/Outdoor
  • Panel/Wall Mount
  • Long Service Life
  • Corrosion resistant
  • Bolt/Clamp Type
  • > 100 M
  • Up to 10 kA

Flash Meter Arrestor Trade Information

  • kolkata
  • 1000 Piece Per Day
  • 7 Days
  • Yes
  • Sample costs shipping and taxes has to be paid by the buyer
  • Standard
  • Western Europe, Australia, North America, Eastern Europe, Central America, Middle East, South America, Asia, Africa
  • Chandigarh, Himachal Pradesh, Andaman and Nicobar Islands, Uttarakhand, Daman and Diu, Dadra and Nagar Haveli, Lakshadweep, South India, East India, West India, Assam, Arunachal Pradesh, Bihar, Delhi, Gujarat, Goa, Haryana, Jammu and Kashmir, Jharkhand, Karnataka, Madhya Pradesh, Maharashtra, Mizoram, Meghalaya, Manipur, Punjab, Pondicherry, Rajasthan, Sikkim, Tamil Nadu, Telangana, Tripura, West Bengal, Nagaland, Uttar Pradesh, North India, Andhra Pradesh, Kerala, Central India, Odisha, Chhattisgarh, All India
  • ISO 9001;2015

Product Description

  • Model : FBA-REG- OXY-RH & FBA-REG- FUEL- LH
  • Application: This device is suitable for Oxygen & Fuel (DA & LPG) Regulator.
  • Model: FBA- Torch- OXY- RH & FBA- Torch- FUEL- LH
  • Application: This device is suitable for Oxygen & Fuel (DA & LPG) Torch

 

Feature:

  • This is Dry type flash back arrestor is to stop or arrest the return of the flame and sealing is done by help of perforated metal filter.
  • This device intended to prevent rupture of the flame arrestor due to sudden built in pressure.
  • This device prevents the flow to return from the downstream side.

 

Operating Instruction:

  • Flashback arrestor should be connected between the hose and each regulator and between the hose and the torch in the correct direction of the flow which to clearly marked on the flashback arrestor.
  • Do not exceed the maximum operating pressure marked on the flashback arrestor for the gas service.
  • All connections should be clean and free of damage, oil, grease and dust.
  • In case of gas return flow: replace the device.
  • Do not attempt to repair flashback arrestor.

 

Model

Gas

Working pressure (max)

FBA- REG- OXY-RH

Oxygen

15 bar/ 220 psi

FBA- REG- FUEL-RH

Fuel (DA & LPG)

15 bar/ 21 psi

FBA- TORCH-OXY-RH

Oxygen

15 bar/ 220 psi

FBA- TORCH-FUEL-RH

Fuel (DA & LPG)

15 bar/ 21 psi




Comprehensive Surge and Lightning Protection

Safeguard your energy meters and connected systems with high-level protection against voltage spikes, surges, and flashes. Whether caused by environmental factors or grid disruptions, the Flash Meter Arrestors superior discharge current capability ensures reliable defense for residential, commercial, and industrial applications.


Engineered for Durability and Versatility

Built with corrosion-resistant materials and designed for installation in diverse environments, this arrestor operates seamlessly between -10C and +60C. Suitable for both indoor and outdoor usage, its robust construction guarantees consistent performance and extended service life.

FAQs of Flash Meter Arrestor:


Q: How is the Flash Meter Arrestor installed?

A: The Flash Meter Arrestor can be easily installed using panel or wall mounting. The device is equipped with bolt or clamp-type connectors, making it suitable for standard metering setups. Installation should be conducted by a qualified electrician as per the manufacturers guidelines.

Q: What is the primary function of this arrestor device?

A: Its main purpose is to shield energy meters and related equipment from high voltage surges, electrical flashes, and lightning strikes. This ensures ongoing system reliability and prolongs the life of your metering infrastructure.

Q: When should I consider installing a Flash Meter Arrestor?

A: Install a Flash Meter Arrestor when your energy meters are at risk of voltage surges, whether due to lightning, power surges, or electrical faults. It is especially recommended for regions prone to frequent storms or unstable power supply.

Q: Where can the Flash Meter Arrestor be used?

A: This device is designed for both indoor and outdoor environments. Its corrosion-resistant finish and insulation allow it to function reliably across various conditions, making it ideal for homes, commercial buildings, and industrial facilities in India.

Q: What is the process for selecting the right arrestor for my application?

A: To choose the appropriate model, consider your systems voltage (230-440 V), current requirements (up to 100 A), and environmental conditions. The arrestor can be customized to fit standard or specific dimensions to match your application needs.

Q: How does this product benefit my electrical installation?

A: By providing robust protection against surges and flashes, the Flash Meter Arrestor reduces equipment downtime, lessens maintenance costs, and ensures consistent meter performance, delivering peace of mind and financial savings over its extended service life.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Flash Back Arrestor' category



Contact Details
HINDMEDICO PRODUCT PRIVATE LIMITED
GST : 19AAGCH8923E1ZE
B No. 5/8, 1st floor, Ashutosh Mukherjee Road, Nearby Landmark: Belur Switch House, Belur, Bally,Howrah - 711202, West Bengal, India
Phone :08045803776
   Call Me Free Send SMS Send Inquiry
Key Personnel
Mr Sumon Das (Partner)
Mobile :08045803776